Maintenance of the Feed System
Check regularly whether the horn cover is damaged. If it is broken, replace it in time in order to prevent the feed system performance may have degraded. A method is recommended to remove water in the feed. First, loose the screws connecting the LNA with the filter, the adapter on the transmit port. Check if water gas existed in the LNA and the adapter or not. If water is found, clean it with a clear cloth carefully. Then removing the marked transmit OMT or the flange A referring, blow away water or moisture inside the horn and the OMT using a blower. Finally, referring to the line marked on the flange, connect the disassembling parts one by one and fasten the screws tightly, replace the damaged radome for a new one.
Shaanxi Probecom Microwave Technology Co.,LTD (abbreviated as Probecom), was founded in 2002, located in International Trade and Logistic Park in Xi’an, we are mainly engaged in the design and manufacture of all types of satellite communication Earth Station Antenna, VSAT Antenna, Ka Series Antenna, Portable Flyaway Antenna, RxO/TVRO Antenna, SNG Antenna, On-the-Move Antenna, Remote Sensing & Telemetry Antenna, Meteorological Radars, High Power and Ultra Wideband Amplifiers (SSPA & TWTA), Microwave Components as well as the related Antenna Control & Tracking System.